diff options
author | Erovia <Erovia@users.noreply.github.com> | 2022-03-10 21:33:41 +0000 |
---|---|---|
committer | GitHub <noreply@github.com> | 2022-03-10 21:33:41 +0000 |
commit | b75f6691a15a78b9c200a88e28792974ca2f9461 (patch) | |
tree | bf336f07dfef692edb6d8fea1d2f14b30a28d6b8 /lib/python | |
parent | 6c40b6856bb843e39bf0992164f41e29ce7ea72c (diff) |
CLI: Fix 'cd' subcommand on Windows (#16610)
The 'cd' subcommand was failing as the current shell's Windows path was
mangled while milc processed it.
Using 'subprocess' directly avoids this issue and an extra layer of
subshell.
Diffstat (limited to 'lib/python')
-rwxr-xr-x | lib/python/qmk/cli/cd.py | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/lib/python/qmk/cli/cd.py b/lib/python/qmk/cli/cd.py index c62c3f56c6..ef03011f1f 100755 --- a/lib/python/qmk/cli/cd.py +++ b/lib/python/qmk/cli/cd.py @@ -2,6 +2,7 @@ """ import sys import os +import subprocess from milc import cli @@ -41,6 +42,6 @@ def cd(cli): # Set the prompt for the new shell qmk_env['MSYS2_PS1'] = qmk_env['PS1'] # Start the new subshell - cli.run([os.environ.get('SHELL', '/usr/bin/bash')], env=qmk_env) + subprocess.run([os.environ.get('SHELL', '/usr/bin/bash')], env=qmk_env) else: cli.log.info("Already within qmk_firmware directory.") |